PT. Totalfire Indonesia

Fire Fighting System
Contractor in Indonesia

PT Totalfire Indonesia designs and installs the full range of water-based fire fighting systems for industrial plants, commercial buildings, high-rise developments, power stations, oil & gas facilities, warehouses, and data centers across Indonesia. From fire hydrant infrastructure that lasts 70–100 years to automatic sprinkler systems that control over 99% of fires — we engineer every system to NFPA and SNI standards, backed by our ISO 9001:2015 and ISO 45001:2018 certifications.

All fire fighting systems are delivered on a full Engineering, Procurement & Construction (EPC) basis — from initial hazard assessment and hydraulic design through installation, commissioning, and regulatory documentation.

Our Fire Fighting System Services

instalasi pemasangan fire hydrant

Fire Hydrant System

Fixed manual suppression infrastructure providing high-volume pressurized water access throughout a facility for trained fire response personnel and the fire department. Systems include indoor box hydrants, outdoor pillar hydrants, Siamese connections, fire pump sets (electric + diesel + jockey), and water storage tanks. Designed per NFPA 14 and SNI 03-1745-2000. Service life: 70–100 years.

Best for: Industrial plants, commercial buildings, warehouses, high-rise developments, power plants, oil & gas facilities.

fire sprinkler sistem proteksi kebakaran

Sprinkler System

Overview of our complete automatic sprinkler system capabilities — covering all system types (wet pipe, dry pipe, pre-action, deluge) and all occupancy hazard classifications per NFPA 13. In buildings fully protected by automatic sprinkler systems, over 99% of fires are controlled by the sprinkler system alone. Designed per NFPA 13 and SNI 03-3989-2000.

Best for: All commercial, industrial, and residential building types requiring automatic fire suppression.

kontraktor wet pipe system

Wet Pipe Sprinkler System

The most widely installed automatic sprinkler system worldwide. Piping permanently filled with pressurized water — individual heads discharge immediately on activation with zero delay. Simplest design, lowest installation cost, lowest maintenance requirements. Recommended for any conditioned building environment in Indonesia’s tropical climate.

Best for: Offices, hotels, hospitals, shopping malls, factories, warehouses, residential towers.

instalasi pemasangan fire hydrant

Dry Pipe Sprinkler System

Air- or nitrogen-charged piping system where water is held at a dry pipe valve and only enters the system after a sprinkler head activates. Specifically designed for spaces where standing water in the piping would freeze or cause accidental leakage damage. Per NFPA 13, the maximum water delivery time is 60 seconds from head activation.

Best for: Cold storage and freezer warehouses, open parking structures, unheated buildings, outdoor canopies, loading docks.

pemasangan water spray system pemadam kebakaran

Water Spray System

Fixed directional water spray system using open nozzles engineered to produce specific spray patterns (oval, fan, full-circle, jet) that envelop three-dimensional equipment from multiple angles simultaneously. Operationally similar to a deluge system but designed to protect specific equipment surfaces rather than floor areas. Designed per NFPA 15.

Best for: Oil-filled transformers, turbine generators, LPG/pressurized gas vessels, storage tank cooling, process equipment, cable trays.

Foam Fire Suppression System

Foam System

Foam-water fire suppression systems that discharge a mixture of water and foam concentrate, creating a persistent foam blanket that smothers the fire, cools the surface, and prevents re-ignition — specifically effective for Class B (flammable liquid) fires where water alone would spread the burning liquid. Available as foam-water sprinkler, foam-water deluge, high-expansion, and AFFF/AR-AFFF systems. Designed per NFPA 11 and NFPA 16.

Best for: Aircraft hangars, flammable liquid storage, oil & gas tank farms, petrochemical plants, fuel loading areas.

Choosing the Right Fire Fighting System

System Activation Primary Use Case NFPA Standard
Fire Hydrant Manual Large-scale suppression; fire department operations NFPA 14
Wet Pipe Sprinkler Automatic Standard occupied buildings, offices, hotels, factories NFPA 13
Dry Pipe Sprinkler Automatic Cold storage, parking structures, outdoor/unheated spaces NFPA 13
Water Spray Automatic (deluge) Transformers, tanks, turbines, process equipment NFPA 15
Foam System Automatic / Manual Flammable liquid fires, hangars, tank farms NFPA 11/16

Not sure which system is right for your facility? Our engineering team provides free initial consultations and system recommendations based on your specific occupancy, hazard classification, and regulatory requirements.

Industries We Serve

  • Industrial Manufacturing — Complete fire fighting infrastructure for factories, process plants, and production facilities
  • Power Generation — Transformer protection, cable tray systems, turbine suppression, and facility hydrant networks for PLN substations and independent power producers
  • Oil & Gas — Tank farm deluge, wellhead protection, compressor stations, LPG vessel cooling, and offshore facility fire fighting systems
  • Commercial Buildings — Integrated sprinkler and hydrant systems for office towers, hotels, shopping malls, and mixed-use developments
  • Healthcare — Life-safety compliant sprinkler systems for hospitals, clinics, and medical facilities
  • Warehouses & Logistics — Ceiling and in-rack sprinkler systems for high-bay storage and distribution centers
  • Cold Chain — Dry pipe systems for refrigerated warehouses, blast freezers, and cold storage facilities
  • Mining — Fire protection for process buildings, fuel storage, conveyor systems, and mining infrastructure
  • Residential — High-rise apartment and condominium sprinkler systems per NFPA 13 and 13R

Related Services

  • Gaseous Fire Suppression System — CO2, FM-200, Novec 1230, and Inert Gas systems for server rooms, data centers, and sensitive equipment environments
  • Detection System — Fire alarm, smoke detection, and heat detection systems integrated with all suppression systems
  • Service & Maintenance — Scheduled inspection and maintenance contracts for all fire fighting systems per NFPA 25

Frequently Asked Questions

Does every building in Indonesia need a fire fighting system?

Indonesian fire safety regulations mandate fire protection systems for most commercial, industrial, and high-rise buildings under Peraturan Menteri Pekerjaan Umum No. 26/PRT/M/2008 and associated SNI standards. The specific system type and scope required depends on the building’s occupancy classification, height, floor area, and use. PT Totalfire Indonesia’s engineering team can advise on the regulatory requirements applicable to your facility.

Can one building need multiple fire fighting systems?

Yes — and this is standard practice for most industrial and commercial facilities. A typical industrial plant might have: a fire hydrant system for the overall site, wet pipe sprinklers in the offices and control building, a dry pipe system in the cold storage area, a water spray system on the transformers, and a foam system in the flammable liquid storage area. PT Totalfire Indonesia designs and installs integrated multi-system fire protection strategies as part of our EPC scope.

How long does fire fighting system installation take?

Installation timelines depend on system complexity, building size, and site conditions. A single-zone wet pipe sprinkler system for a small commercial space can be completed in two to four weeks. A complete fire fighting infrastructure package for a large industrial facility — including hydrant network, sprinkler systems, and water spray systems — is a multi-month project developed on a detailed project schedule during the engineering phase. Contact our team for a project-specific timeline estimate.

What is the difference between a fire fighting system and a fire suppression system?

“Fire fighting system” typically refers to water-based active systems — sprinklers, hydrants, water spray, and foam systems — that use water or foam-water as the suppression agent. “Fire suppression system” is a broader term that also encompasses gaseous systems (CO2, FM-200, Novec 1230, inert gas) that use gas rather than water. PT Totalfire Indonesia provides both categories of systems. For gaseous suppression solutions, visit our Gaseous Fire Suppression System page.

PT. Totalfire Indonesia

PT. Totalfire Indonesia, established in May 2005, is a trusted fire protection system contractor in Jakarta, Indonesia. As a fire protection specialist with ISO 45001 and ISO 9001 certification, we provide engineering, installation, and maintenance services for fire protection systems across commercial and industrial projects, ensuring compliance with NFPA and SNI standards.

Market Range

Industrial Building
Power Plant
Mining Company
Oil and Gas Company
Telecommunication Company
Commercial Building
Residential Building

Contact Us

Ruko Prominence Alam Sutera, Blok 38E No.49

Jl Jalur Sutera, Panunggangan Timur, Pinang

Tangerang Selatan, Banten - Indonesia 15325

Telephone : (+6221) 300 525 33
FAX : (+6221) 300 525 32
E-mail : info@totalfire.co.id